QB82 & QB102 Hybrid Solar Inverter 8.2-10.2kW 48V

8.2kW10.2kWQB82-48QB102-4848V DC230V ACMPPTOFF GRID
In Stock Price on Request MOQ 1 UNIT

IDEEI QB82-48 (8.2kW) and QB102-48 (10.2kW) dual-PV hybrid solar inverters share a 48V battery system with pure sine-wave 220-240V output and 160A solar charging, for use with or without batteries.

  • F018.2kW (QB82) / 10.2kW (QB102) rated pure sine-wave output
  • F02Dual PV input with 5,400W + 5,400W published capacity
  • F0348V DC nominal battery system
  • F0490-450V DC MPPT working range
  • F05500V DC maximum PV input
DOC DS-DESCSERIES SOLAR INVERTERREV 2026-A
IDEEI · Solar Energy Systems

IDEEI QB82 & QB102 8.2-10.2kW Dual-PV Hybrid Solar Inverter

The QB82-48 and QB102-48 provide 8.2kW and 10.2kW of hybrid pure sine-wave power with dual photovoltaic inputs and a 48V battery system for both models, running with or without a battery bank. The published data sheet confirms the electrical values in the model table; load surge and battery communication still require project review.

Hybrid8.2-10.2kWDual PV48V battery160A solar charging

Key Features & Benefits

Dual PV Inputs, 5,400W + 5,400W

Each model carries two independent PV inputs of 5,400W each, with a 90–450V DC MPPT range, 120V DC start voltage and 2 × 18A maximum PV input current. Two strings — for example east and west roofs — can each work at their own optimum instead of sharing one tracker.

48V Only, Built for Larger Loads

Both models use a 48V DC battery system: the QB82-48 delivers 8.2kW / 8.2kVA at 35.6A nominal output current, the QB102-48 delivers 10.2kW / 10.2kVA at 44.3A. This is the step up from the 24V/48V QB42/62 pair for larger homes, clinics and workshops with motor loads.

160A Solar Charging, 140A AC Charging

Maximum solar charge current is 160A and maximum AC charge current is 140A, at 94% DC-to-AC efficiency. Check the surge behaviour of the largest motor against the model’s rated output before ordering, not just the sum of nameplate watts.

With or Without a Battery

Both models run with or without a battery bank. Off-grid mode is the default and grid-tie hybrid mode is LCD-selectable, feeding excess solar to the grid; communication options are RS232 / RS485 / Wi-Fi / GPRS with lithium-battery support.

Verified Model Selection

The table separates verified published data from project-dependent choices. Match the product by electrical ratings and application conditions; do not select from the headline power value alone.

Model Rated output Nominal output current Battery PV capacity MPPT range
QB82-48 8.2kW / 8.2kVA 35.6A 48V DC 5,400W + 5,400W 90-450V DC
QB102-48 10.2kW / 10.2kVA 44.3A 48V DC 5,400W + 5,400W 90-450V DC
Selection note: Confirm that both PV trackers, battery charge limits and the total connected load are compatible with the final system design.

Technical Specifications

Item Verified specification
AC output 220/230/240V AC pure sine wave
PV nominal / maximum voltage 360V / 500V DC
PV start voltage 120V DC
Maximum PV input current 2 × 18A
Maximum solar charge current 160A
Maximum AC charge current 140A
DC-to-AC efficiency 94%
Communication RS232 / RS485 / Wi-Fi / GPRS / lithium battery
Operating modes Off-grid mode (default) and grid-tie hybrid mode, LCD selectable; hybrid mode feeds excess solar to the grid
Options / project configuration: Battery BMS, Wi-Fi/GPRS hardware, utility/generator switching and external protection devices must be confirmed for the selected installation.

Typical Applications

Homes and residential backup
Farms and rural facilities
Small offices and shops
Telecom and monitoring loads
Workshops and light commercial loads
Sites with unstable or unavailable grid power

Information Required for Selection

  • Continuous and surge load power, load type and simultaneous-load requirement
  • Required output voltage, phase and frequency
  • PV module Voc, Vmp, current, wattage and proposed series/parallel layout
  • Battery chemistry, nominal voltage, capacity and BMS protocol when batteries are used
  • Utility or generator input voltage and required source priority
  • Site temperature, altitude, enclosure requirement, quantity and destination

A dependable quotation requires the complete operating profile, not only the nominal power. IDEEI reviews voltage, current, source or motor data, duty, environment, required options and destination together so the final configuration, accessories, protection devices and commercial scope can be stated clearly.

Engineering & Installation Notes

Separate continuous load from startup surge loads such as pumps, compressors and motors. Check the PV string at the lowest expected temperature so open-circuit voltage remains below the product limit. Where a battery is used, match chemistry, nominal voltage, charge current and communication protocol. Source priority, transfer behavior, neutral arrangement and generator compatibility must be confirmed for the complete system.

Installation and commissioning must be completed by qualified electrical personnel. Isolate all energy sources before wiring, verify terminal functions against the current manual, provide protective devices and grounding, and apply the published derating guidance for altitude, temperature, enclosure and cable length. Product-page data supports preliminary selection and does not replace project engineering or local code compliance.

Frequently Asked Questions

Can this inverter work without batteries?

Yes. The QB82-48 and QB102-48 run with or without a battery bank. Without batteries, daytime loads run from PV (and utility or generator where connected) as long as the available source can support the connected load; battery-free operation provides no night-time backup. Confirm the intended operating mode before wiring.

How should the PV array be sized?

Use the selected model’s permitted PV voltage window and maximum open-circuit voltage. Check cold-weather Voc, operating Vmp, current, total array power and local irradiance rather than selecting from inverter kW alone.

Can utility power or a generator be connected?

Supported AC input and source-priority modes depend on the selected series. The transfer arrangement, protection devices and neutral/earthing scheme must be confirmed for the installation.

Is Wi-Fi or battery BMS communication standard?

Communication is model- and project-dependent. Confirm Wi-Fi, GPRS, RS232, RS485 and the required lithium-battery protocol before ordering.

What information is needed for a quotation?

Send the load list, surge loads, required output voltage and phase, PV module data, battery information, backup-source data, operating schedule, quantity and delivery country.

Engineering selection & bulk orders

Send the nameplate. We size the drive.

Send the required electrical and application data, quantity and destination. Our team will confirm the suitable model, options and quotation scope.

Request a Quote
Email Us
WhatsApp

Email: [email protected] · WhatsApp: +86 183 5724 1165

Related reading

For the voltage decision in full, see our Hybrid Solar Inverter Buying Guide 2026 — it compares 24V and 48V battery systems across the QB range from 4.2kW to 10.2kW.

Also see our new battery-sizing guide: 24V vs 48V Battery Sizing for QB Hybrid Inverters

Talk to an engineerFACTORY-DIRECT · MON–SAT 8:30–17:30 (GMT+8)

Related Models

( REL ) — SOLAR INVERTER
/02 IDEEI QB-Hi 2 Off-Grid Solar Inverter 4-11kW IGBT 4kW · 5.5kW · 7.5kW In StockRFQ
/03 IDEEI QB-Hi Off-Grid Solar Inverter 5-11kW MPPT 5kW · 7kW · 11kW In StockRFQ
/04 QB42 & QB62 Hybrid Solar Inverter 4.2-6.2kW 24V/48V 4.2kW · 6.2kW · QB42-24 In StockRFQ