
QB100-PV is a solar pump inverter platform for 0.4–37kW water-pumping applications. Verified plastic-shell range · 220V single-phase (SS2) and 3-phase (S2) plus 380–400V 3-phase branches use MPPT-based solar control and pump-oriented protection. Send the pump nameplate, PV module data, head, flow and cable length so IDEEI can confirm the exact order model.
The QB100-PV converts solar-array power into controlled AC output for water pumps across 0.4–37kW. Its verified plastic-shell model branches cover 220V single-phase (SS2) and 3-phase (S2) plus 380–400V 3-phase output; final selection must follow the pump current, motor type and PV string data.
The product catalog states solar maximum-power-point tracking efficiency up to 99%.
The controller can start or sleep automatically according to available PV power.
Verified functions include PV overvoltage, overcurrent and over-temperature derating.
GPRS remote monitoring and IP54 cabinet versions are listed as options.
Three branch families sit on this one plastic-shell page, and the branch — not the kilowatt headline — decides the order. SS2 covers 220V single-phase output, S2 covers 220V three-phase output, and the third family covers 380–400V three-phase output; every branch runs direct PV pumping with MPPT tracking stated up to 99%, automatic start and sleep by available PV power, and PV overvoltage, overcurrent and over-temperature derating protection. GPRS remote monitoring and IP54 cabinet versions are listed options, not standard scope — confirm them on the quotation. Match the order by pump rated current, voltage and phase in the table below.
| Order reference | Pump power | Output | PV input class |
|---|---|---|---|
| QB100-PV-0.4KW | 0.4kW | 3-phase 220V output | DC 180–450V |
| QB100-PV-0.75KW | 0.75kW | 3-phase 220V output | DC 180–450V |
| QB100-PV-1.5KW | 1.5kW | 3-phase 220V output | DC 180–450V |
| QB100-PV-2.2KW | 2.2kW | 3-phase 220V output | DC 180–450V |
| QB100-PV-4KW | 4kW | 3-phase 220V output | DC 180–450V |
| QB100-PV-5.5KW | 5.5kW | 3-phase 220V output | DC 180–450V |
| QB100-PV-7.5KW | 7.5kW | 3-phase 220V output | DC 180–450V |
| QB100-PV-0.4KW | 0.4kW | single-phase 220V output | DC 180–450V |
| QB100-PV-0.75KW | 0.75kW | single-phase 220V output | DC 180–450V |
| QB100-PV-1.5KW | 1.5kW | single-phase 220V output | DC 180–450V |
| QB100-PV-2.2KW | 2.2kW | single-phase 220V output | DC 180–450V |
| QB100-PV-4KW | 4kW | single-phase 220V output | DC 180–450V |
| QB100-PV-5.5KW | 5.5kW | single-phase 220V output | DC 180–450V |
| QB100-PV-0.75KW | 0.75kW | 3-phase 380–400V output | DC 250–900V |
| QB100-PV-1.5KW | 1.5kW | 3-phase 380–400V output | DC 250–900V |
| QB100-PV-2.2KW | 2.2kW | 3-phase 380–400V output | DC 250–900V |
| QB100-PV-4KW | 4kW | 3-phase 380–400V output | DC 250–900V |
| QB100-PV-5.5KW | 5.5kW | 3-phase 380–400V output | DC 250–900V |
| QB100-PV-7.5KW | 7.5kW | 3-phase 380–400V output | DC 250–900V |
| QB100-PV-11KW | 11kW | 3-phase 380–400V output | DC 250–900V |
| QB100-PV-15KW | 15kW | 3-phase 380–400V output | DC 250–900V |
| QB100-PV-18.5KW | 18.5kW | 3-phase 380–400V output | DC 250–900V |
| QB100-PV-22KW | 22kW | 3-phase 380–400V output | DC 250–900V |
| QB100-PV-30KW | 30kW | 3-phase 380–400V output | DC 250–900V |
| QB100-PV-37KW | 37kW | 3-phase 380–400V output | DC 250–900V |
| Item | Verified specification |
|---|---|
| MPPT efficiency | Up to 99% |
For a dependable quotation, also confirm the installation altitude, ambient temperature, enclosure requirement, daily operating schedule, water-source conditions and whether utility or generator backup is required. These details affect derating, cable selection, protection devices and the final AC/DC system design.
Installation and commissioning must be completed by qualified electrical personnel. Verify polarity, grounding, protective devices, PV open-circuit voltage and motor wiring before energizing. Apply the manual derating and reactor guidance for temperature, altitude and long cable runs.
Yes. The QB100-PV S2 is designed for PV-powered pumping. Confirm the PV string voltage remains inside the verified range for the selected 220V class · 3-phase 220V output model.
Backup input depends on the selected branch and wiring configuration. Do not connect sources simultaneously unless the selected model and protection arrangement explicitly support it.
Check the pump nameplate current, rated voltage, phase, motor type, head, flow and cable length. The selected inverter current must meet the motor requirement.
The standard solar-pumping architecture can operate directly from the PV array. Battery use is not required unless a separate project design specifies it.
Remote communication is optional or model-dependent. Confirm the required GPRS, 4G or Wi-Fi module before ordering.
Send the pump nameplate, PV module data, required head and flow, cable length and quantity. Our team will confirm the suitable model and project configuration.
Email: [email protected] · WhatsApp: +86 183 5724 1165
For the pump-sizing decision in full, see our What Size Solar Pump Inverter Do I Need? A Practical Sizing Guide with HP/kW Table — it gives the HP/kW sizing table for choosing a solar pump inverter.
Questions about model selection, bulk pricing or shipping? Chat with us directly.
Start WhatsApp Chat →Questions about model selection, bulk pricing or shipping? Chat with us directly.
Start WhatsApp Chat →