The IDEEI SY200PV solar pump inverter converts single-phase 220V AC or high-voltage solar DC into three-phase 380V output for 4-15kW asynchronous water pumps. It combines MPPT control, AC/DC hybrid input capability, water-level sensor support and pump-protection functions for irrigation, domestic water supply and remote pumping projects.

  • F01220V to 380V Boost: Single-phase 200-240V AC input and three-phase 380V output
  • F024-15kW Range: Five verified models for asynchronous three-phase water pumps
  • F03High-Voltage Solar Input: 800V DC maximum and 300-750V recommended operating range
  • F0499% MPPT: Advanced tracking software maximizes available photovoltaic power
  • F05AC/DC Hybrid Operation: Supports solar PV and single-phase grid input according to the approved wiring
DOC DS-DESCSERIES SOLAR PUMP INVERTERREV 2026-A
IDEEI · Solar Pumping Control

IDEEI SY200PV Solar Pump Inverter 4-15kW

The SY200PV solar pump inverter converts single-phase 220V AC or suitable high-voltage photovoltaic DC into three-phase 380V output for asynchronous water pumps. Five verified power models combine MPPT control, hybrid-source capability, sensor inputs and pump-oriented protection for dependable water delivery.

4-15kW
1PH 220V input
3PH 380V output
99% MPPT

Why Choose the SY200PV Solar Pump Inverter?

220V to 380V Boost Output

The verified -4 platform accepts single-phase 200-240V AC and supplies three-phase 380V to a compatible asynchronous pump motor. This is useful where only single-phase utility power is available but the installed water pump requires three-phase power.

Advanced MPPT Control

MPPT software is stated at up to 99% efficiency. The controller adjusts pump frequency to the available solar power so a correctly designed PV array can deliver useful water across changing irradiance conditions.

Solar and AC Hybrid Input

The published wiring supports PV DC and single-phase AC input. Source switching and the required protection diode must follow the approved wiring diagram; the two source switches must not be operated together where the diagram prohibits it.

Pump Protection and Sensors

Dry-run, overvoltage, undervoltage, overload, surge, temperature and phase-loss protection are listed. Water-level and radiation sensor inputs support automatic pumping logic when correctly commissioned.

Verified Model Selection

All five models use the published single-phase 220V input and three-phase 380V output architecture. Select the inverter by the pump nameplate current and duty, not by motor power alone.

Model Rated power Horsepower Rated input current Rated output current
004G-4 4kW 5.5HP 30A 9.5A
5R5G-4 5.5kW 7.5HP 45A 14A
7R5G-4 7.5kW 10HP 56A 17A
011G-4 11kW 15HP 85A 25A
015G-4 15kW 20HP 110A 32A
Selection note: Match the inverter output current to the pump nameplate and confirm motor type. The supplied SY200 sheet identifies asynchronous motors; PMSM or single-phase pump operation is not established for this series.

Technical Specifications

Item Verified specification
AC input Single-phase 200V (-10%) to 240V (+10%)
PV input 800V DC maximum; 300V start; 250V lowest working voltage
Recommended PV range 300-750V DC; recommended MPP voltage 550V DC
Rated output Three-phase 380V AC
Output frequency 0-400Hz
MPPT efficiency Up to 99% stated
Installation and cooling Wall mounting; fan cooling; IP20
Environment -10°C to +50°C; below 1000m without altitude derating guidance stated on the sheet
Options / project configuration: 4G, Wi-Fi and GPRS remote monitoring require the corresponding communication module and network service. Sensor type, source-switching hardware, lightning protection, enclosure and external isolators must be confirmed for the selected site.

Typical Applications

Agricultural irrigation
Desert and remote water supply
Household and village water supply
Livestock watering
Reservoir transfer systems
Sites with single-phase grid backup

Information Required for Model Selection

  • Pump nameplate power, rated voltage, phase, current and motor type
  • Required head, flow, daily water volume and operating hours
  • PV module Voc, Vmp, Imp, wattage and proposed string configuration
  • Lowest expected site temperature for PV open-circuit voltage checking
  • Grid or generator backup voltage and required source priority
  • Cable length, ambient temperature, altitude, enclosure, quantity and destination

Send the complete pump and PV data rather than selecting from the headline kW alone. Motor current, PV voltage at temperature, cable voltage drop, pump duty and source-switching arrangement determine the final inverter, protective devices and commissioning parameters.

Installation and Derating Notes

The IP20 enclosure is intended for installation inside a clean, dry and ventilated electrical area or suitable protective cabinet. The sheet states operation from -10°C to +50°C and requires 1% derating for every 1°C above 40°C. The installation altitude is stated as below 1000m; confirm additional derating for higher sites.

Qualified personnel must verify grounding, AC and DC isolation, polarity, pump wiring and lightning protection before energizing. Keep the cold-weather PV open-circuit voltage below the 800V DC maximum. Follow the published source-switching and protection-diode diagram: incorrect simultaneous switching can damage the photovoltaic array.

Frequently Asked Questions

Can SY200PV convert 220V single-phase power to a 380V three-phase pump?

Yes. The verified -4 model branch accepts single-phase 200-240V AC and provides three-phase 380V output. The pump must be an appropriate three-phase asynchronous motor within the selected model current.

What photovoltaic voltage should be used?

The recommended DC input range is 300-750V, the stated start voltage is 300V and the recommended MPP voltage is 550V. The array must remain below 800V open circuit under the coldest expected condition.

Can solar and grid power both be connected?

The product sheet shows PV and grid inputs for hybrid operation. Source switches and the protection diode must follow the approved diagram. Do not improvise parallel source connections or operate prohibited switches simultaneously.

Does it include dry-run and tank-level control?

Dry-run protection is listed, and the wiring diagram provides high- and low-water-level switch inputs. Confirm the sensor type, logic and commissioning settings for the actual well and storage tank.

Is remote monitoring included as standard?

The series supports 4G, Wi-Fi or GPRS modules for mobile-phone and browser monitoring. The module, antenna, network compatibility and platform access are project-dependent and must be confirmed before ordering.

Engineering selection and bulk orders

Send the nameplate. We size the drive.

Send the pump nameplate, PV module data, required head and flow, cable length, AC backup requirement, quantity and destination. Our engineering team will confirm the suitable SY200PV model and project configuration.

Email: sales@ideeishop.com · WhatsApp: +86 183 5724 1165

Talk to an engineerFACTORY-DIRECT · MON–SAT 8:30–17:30 (GMT+8)

Related Models

( REL ) — SOLAR PUMP INVERTER
/01 IDEEI 500 Solar Water Pump VFD 0.4–315kW MPPT Controller 500 Series · 0.4–315kW · 220–240V In StockRFQ
/02 IDEEI S319 Solar Pump Inverter 0.4–315kW MPPT AC/DC S319 Series · 0.4–315kW · 220–240V In StockRFQ
/03 IDEEI S318 Solar Pump Inverter 0.4–500kW MPPT RS485 S318 Series · 0.4–500kW · 220–240V In StockRFQ
/04 IDEEI LF-100 Low-Voltage Solar Pump Controller 40–130V DC MPPT LF-100 · 40V DC · 48V DC In StockRFQ