FACTORY ONLINE — HAIYAN, ZHEJIANG
MON–SAT 8:30–17:30 (GMT+8) SALES@IDEEISHOP.COM WA +86 183 5724 1165
Get a Quote→ Contact
Home/Products/solar pump inverter/IDEEI 500 Solar Water Pump VFD 0.4–315kW MPPT Controller
00 — SOLAR PUMP INVERTER

IDEEI 500 Solar Water Pump VFD 0.4–315kW MPPT Controller

500 Series0.4–315kW220–240V380–440V1 Phase3 PhaseMPPTAC/DC
In Stock Price on Request MOQ 1 UNIT

500 Series is an IDEEI photovoltaic water-pump inverter covering 0.4–315kW across the catalog voltage branches. The page uses only the functions and electrical ranges printed in Product Catelog. Send the pump and PV nameplates so the exact order code, rated current and project options can be confirmed.

  • F01Efficient MPPT Algorithm: The catalog describes a built-in efficient MPPT algorithm up to 99%.
  • F02Automatic Start & Sleep: Automatic start, stop and sleep functions are listed.
  • F03Concise User Menu: The series is positioned with a simple user interface.
  • F04Water-Level Control: Port water-level control is listed for pump-system automation.
DOC DS-DESCSERIES SOLAR PUMP INVERTERREV 2026-A
IDEEI · Solar Pumping Control

IDEEI 500 Solar Water Pump VFD 0.4–315kW MPPT Controller

The 500 Series is designed for photovoltaic water-pump applications across 0.4–315kW. The approved catalog confirms the power and voltage branches below; exact SKU codes and current ratings remain selection-dependent.

0.4–315kW220–240V / 380–440VMPPT up to 99%Water-level control

Key Features & Benefits

Efficient MPPT Algorithm

The catalog describes a built-in efficient MPPT algorithm up to 99%.

Automatic Start & Sleep

Automatic start, stop and sleep functions are listed.

Concise User Menu

The series is positioned with a simple user interface.

Water-Level Control

Port water-level control is listed for pump-system automation.

Model Selection

The table below keeps every verified power or model branch visible. Match the inverter by pump rated current, voltage, phase and application conditions—not by kW alone.

Catalog branch Power range Output phase Voltage class Order code
AC 1PH 220–240V 0.4–7.5kW Single phase 220–240V Confirm exact order model
AC 3PH 220–240V 0.4–15kW Three phase 220–240V Confirm exact order model
AC 3PH 380–440V 0.4–315kW Three phase 380–440V Confirm exact order model
Selection note: The catalog publishes power ranges by voltage and phase but does not list every discrete order code. Confirm the exact model from the pump current, voltage, motor type and PV string.

Technical Specifications

Item Verified specification
Catalog power branches AC 1PH 220–240V: 0.4–7.5kW; AC 3PH 220–240V: 0.4–15kW; AC 3PH 380–440V: 0.4–315kW
Options / project configuration: Any feature described as optional or customized—including Wi-Fi, GPRS, timer or AC/DC mode—must be confirmed for the selected order model.

Typical Applications

Urban water supply
Desert water management
Grassland animal husbandry
Aquaculture water supply
Agricultural irrigation
Remote-area pumping

Information Required for Model Selection

  • Pump rated power, voltage, phase and full-load current
  • Pump type and motor type (induction, PMSM or single-phase)
  • Required head, flow and daily operating time
  • PV module Voc, Vmp, power and planned series/parallel layout
  • Grid or generator backup requirement
  • Cable length, site altitude, ambient temperature and enclosure requirement

For a dependable quotation, also confirm the installation altitude, ambient temperature, enclosure requirement, daily operating schedule, water-source conditions and whether utility or generator backup is required. These details affect derating, cable selection, protection devices and the final AC/DC system design.

Installation & Derating Notes

Installation and commissioning must be completed by qualified electrical personnel. Verify polarity, grounding, protective devices, PV open-circuit voltage and motor wiring before energizing. Apply the manual derating and reactor guidance for temperature, altitude and long cable runs.

Frequently Asked Questions

Can the inverter run a pump directly from solar panels?

Yes. The 500 Series is designed for PV-powered pumping. Confirm the PV string voltage remains inside the verified range for the selected 220–240V and 380–440V branches model.

Can grid power or a generator be used as backup?

Backup input depends on the selected branch and wiring configuration. Do not connect sources simultaneously unless the selected model and protection arrangement explicitly support it.

How should the inverter power be selected?

Check the pump nameplate current, rated voltage, phase, motor type, head, flow and cable length. The selected inverter current must meet the motor requirement.

Does the system need batteries?

The standard solar-pumping architecture can operate directly from the PV array. Battery use is not required unless a separate project design specifies it.

Is remote monitoring standard?

Remote communication is optional or model-dependent. Confirm the required GPRS, 4G or Wi-Fi module before ordering.

Engineering selection & bulk orders

Send the nameplate. We size the drive.

Send the pump nameplate, PV module data, required head and flow, cable length and quantity. Our team will confirm the suitable model and project configuration.

Email Us
WhatsApp

Email: sales@ideeishop.com · WhatsApp: +86 183 5724 1165

Talk to an engineerFACTORY-DIRECT · MON–SAT 8:30–17:30 (GMT+8)

Related Models

( REL ) — SOLAR PUMP INVERTER
/02 IDEEI S319 Solar Pump Inverter 0.4–315kW MPPT AC/DC S319 Series · 0.4–315kW · 220–240V In StockRFQ
/03 IDEEI S318 Solar Pump Inverter 0.4–500kW MPPT RS485 S318 Series · 0.4–500kW · 220–240V In StockRFQ
/04 IDEEI LF-100 Low-Voltage Solar Pump Controller 40–130V DC MPPT LF-100 · 40V DC · 48V DC In StockRFQ