2.2kW3.7kW5.5kW7.5kW11kW15kW
In Stock Price on Request MOQ 1 UNIT

Open-loop elevator inverter for 2.2kW to 15kW three-phase 380V asynchronous motor systems. Sensorless vector control requires no encoder and provides 180% startup torque at 0.5Hz, elevator safety functions and flexible S-curve motion control.

  • F01Sensorless vector control without encoder feedback
  • F02180% startup torque at 0.5Hz
  • F031:100 speed adjustment range
  • F04±0.5% speed stability accuracy
  • F05Asynchronous elevator motor control
DOC DS-DESCSERIES ELEVATOR INVERTERREV 2026-A

11LIFT Open-Loop Elevator Inverter

The IDEEI open-loop elevator inverter uses sensorless vector control (SVC) for asynchronous elevator motors without encoder feedback. The 2.2kW to 15kW, three-phase 380-440V range combines practical commissioning with elevator-specific brake, contactor, overspeed and speed-deviation functions.

Encoder-Free SVC
180% Torque at 0.5Hz
2.2-15kW
380-440V 3-Phase

Open-Loop Control Features

🔧 Encoder-Free Installation

SVC estimates motor operation without an encoder or PG card, reducing feedback wiring and simplifying maintenance for suitable asynchronous motor applications.

⚡ Strong Low-Speed Torque

Up to 180% startup torque at 0.5Hz and a 1:100 speed range support controlled acceleration and dependable low-speed operation.

🛡️ Elevator Protection

The drive includes brake control, contactor control, overspeed protection, slow-down judgment, speed-deviation detection and motor-overheat monitoring.

🏢 Flexible Ride Curves

Linear and S-curve acceleration, four acceleration/deceleration groups and up to eight preset speeds support application-specific motion tuning.

Open-Loop Performance

Parameter SVC Specification Application Value
Feedback No encoder required Simpler wiring and service
Startup torque 180% at 0.5Hz Strong low-speed starting performance
Speed range 1:100 Practical elevator motion adjustment
Speed stability ±0.5% Suitable for non-feedback applications
Recommended motor Asynchronous motor For PMSM or higher precision, select closed loop

Model Selection – Three-Phase 380V

Model Motor Power Capacity Input Current Output Current
Drive-2.2KW-4 2.2kW 4.0kVA 6.5A 5.1A
Drive-3.7KW-4 3.7kW 5.9kVA 10.5A 9.0A
Drive-5.5KW-4 5.5kW 8.9kVA 14.8A 13.0A
Drive-7.5KW-4 7.5kW 11.0kVA 20.5A 18.0A
Drive-11KW-4 11kW 17.0kVA 29.0A 27.0A
Drive-15KW-4 15kW 21.0kVA 36.0A 33.0A
Standard within this listed range: 15kW and below models include a built-in braking unit; connect the correctly selected external braking resistor. The product introduction also specifies a built-in DC reactor.
Application boundary: open-loop SVC does not use encoder feedback. Choose the closed-loop configuration when the project uses a PMSM, requires direct feedback, or needs the highest low-speed precision.

Applications and Selection Information

Suitable for asynchronous-motor passenger elevators, freight elevators, service lifts and modernization projects where encoder-free control is appropriate. Provide the motor nameplate, rated current, rated speed, elevator load, travel speed, braking resistor requirement, power supply, quantity and destination before selection.

Installation conditions: rated operation is below 1,000m altitude and from -10°C to 40°C. Derate 1% for every additional 100m above 1,000m and derate above 40°C; the stated maximum ambient temperature is 50°C.

Frequently Asked Questions

Does open-loop SVC need an encoder?
No. SVC operates without encoder feedback, reducing feedback wiring and PG-card requirements.
Can the open-loop version control a PMSM?
The manual states that synchronous-motor operation requires encoder feedback. Select the closed-loop configuration for PMSM applications.
How does it differ from the closed-loop version?
SVC provides 180% torque at 0.5Hz, a 1:100 speed range and ±0.5% speed stability. FVC uses encoder feedback for 200% torque at 0Hz, 1:1000 range and ±0.05% stability.
Is an external braking resistor required?
Yes. The listed models have a built-in braking unit, but a correctly sized external braking resistor must be connected.

Get Open-Loop Model Selection Support

Send the asynchronous motor nameplate, elevator load, speed, quantity and destination country for configuration confirmation and quotation.

Email UsWhatsApp

Talk to an engineerFACTORY-DIRECT · MON–SAT 8:30–17:30 (GMT+8)

Related Models

( REL ) — ELEVATOR INVERTER