FACTORY ONLINE — HAIYAN, ZHEJIANG
MON–SAT 8:30–17:30 (GMT+8) [email protected] WA +86 183 5724 1165
Get a Quote→ Contact
Home/Products/solar pump inverter/QB100-PV Solar Pump Inverter White Plastic Shell 0.4-37kW
07 — SOLAR PUMP INVERTER

QB100-PV Solar Pump Inverter White Plastic Shell 0.4-37kW

0.4kW0.75kW1.5kW2.2kW4kW5.5kW7.5kW11kW15kW18.5kW22kW30kW37kWQB100-PVWhitePlastic Shell220V400V3 Phase
In Stock Price on Request MOQ 1 UNIT

0.4-37kW white plastic-shell MPPT solar pumping, 220V / 400V, single-phase and 3-phase output for agriculture irrigation, farms and deep wells.

  • F0199% MPPT Tracking: The product catalog states solar maximum-power-point tracking efficiency up to 99%.
  • F02Automatic Solar Operation: The controller can start or sleep automatically according to available PV power.
  • F03Pump & Drive Protection: Verified functions include PV overvoltage, overcurrent and over-temperature derating.
  • F04Communication & Enclosure Options: GPRS remote monitoring and IP54 cabinet versions are listed as options.
DOC DS-DESCSERIES SOLAR PUMP INVERTERREV 2026-A
IDEEI · Solar Pumping Control

QB100-PV Solar Pump Inverter White Plastic Shell 0.4-37kW

The QB100-PV converts solar-array power into controlled AC output for water pumps across 0.4–37kW. Its verified white plastic-shell model branches cover 220V single-phase (SS2) and 3-phase (S2) plus 380–400V 3-phase output; final selection must follow the pump current, motor type and PV string data.

0.4–37kWWhite plastic shell · 220V + 380–400VMPPT controlDirect PV pumping

Key Features & Benefits

99% MPPT Tracking

The product catalog states solar maximum-power-point tracking efficiency up to 99%.

Automatic Solar Operation

The controller can start or sleep automatically according to available PV power.

Pump & Drive Protection

Verified functions include PV overvoltage, overcurrent and over-temperature derating.

Communication & Enclosure Options

GPRS remote monitoring and IP54 cabinet versions are listed as options.

Model Selection

The table below keeps every verified power or model branch visible. Match the inverter by pump rated current, voltage, phase and application conditions—not by kW alone.

Order reference Pump power Output PV input class
QB100-0R4G-S2-PV 0.4kW 3-phase 220V output DC 180–450V
QB100-0R7G-S2-PV 0.75kW 3-phase 220V output DC 180–450V
QB100-1R5G-S2-PV 1.5kW 3-phase 220V output DC 180–450V
QB100-2R2G-S2-PV 2.2kW 3-phase 220V output DC 180–450V
QB100-004G-2-PV 4kW 3-phase 220V output DC 180–450V
QB100-5R5G-2-PV 5.5kW 3-phase 220V output DC 180–450V
QB100-7R5G-2-PV 7.5kW 3-phase 220V output DC 180–450V
QB100-0R4G-SS2-PV 0.4kW single-phase 220V output DC 180–450V
QB100-0R7G-SS2-PV 0.75kW single-phase 220V output DC 180–450V
QB100-1R5G-SS2-PV 1.5kW single-phase 220V output DC 180–450V
QB100-2R2G-SS2-PV 2.2kW single-phase 220V output DC 180–450V
QB100-PV-4KW (SS2) 4kW single-phase 220V output DC 180–450V
QB100-PV-5.5KW (SS2) 5.5kW single-phase 220V output DC 180–450V
QB100-0R7G-4-PV 0.75kW 3-phase 380–400V output DC 250–900V
QB100-1R5G-4-PV 1.5kW 3-phase 380–400V output DC 250–900V
QB100-2R2G-4-PV 2.2kW 3-phase 380–400V output DC 250–900V
QB100-004G-4-PV 4kW 3-phase 380–400V output DC 250–900V
QB100-5R5G-4-PV 5.5kW 3-phase 380–400V output DC 250–900V
QB100-7R5G-4-PV 7.5kW 3-phase 380–400V output DC 250–900V
QB100-011G-4-PV 11kW 3-phase 380–400V output DC 250–900V
QB100-015G-4-PV 15kW 3-phase 380–400V output DC 250–900V
QB100-018G-4-PV 18.5kW 3-phase 380–400V output DC 250–900V
QB100-022G-4-PV 22kW 3-phase 380–400V output DC 250–900V
QB100-030G-4-PV 30kW 3-phase 380–400V output DC 250–900V
QB100-037G-4-PV 37kW 3-phase 380–400V output DC 250–900V
Selection note: Confirm whether the pump requires single-phase or three-phase output. The S2 and SS2 suffixes are not interchangeable.

Technical Specifications

Item Verified specification
PV input class DC 180–450V (220V models) / DC 250–900V (400V models)
AC class 220V / 380–400V
Output Single-phase 220V (SS2) / 3-phase 220V (S2) / 3-phase 380–400V
MPPT efficiency Up to 99%
Standard enclosure White plastic housing
Options / project configuration: AC/DC simultaneous access requires customization. GPRS monitoring, IP54 cabinet, boost module availability and synchronous-pump control must be confirmed before order.

Typical Applications

Agricultural irrigation
Borehole and deep-well pumps
Livestock water supply
Reservoir and tank filling
Rural water supply
Pond and forestry irrigation

Information Required for Model Selection

  • Pump rated power, voltage, phase and full-load current
  • Pump type and motor type (induction, PMSM or single-phase)
  • Required head, flow and daily operating time
  • PV module Voc, Vmp, power and planned series/parallel layout
  • Grid or generator backup requirement
  • Cable length, site altitude, ambient temperature and enclosure requirement

For a dependable quotation, also confirm the installation altitude, ambient temperature, enclosure requirement, daily operating schedule, water-source conditions and whether utility or generator backup is required. These details affect derating, cable selection, protection devices and the final AC/DC system design.

Installation & Derating Notes

Installation and commissioning must be completed by qualified electrical personnel. Verify polarity, grounding, protective devices, PV open-circuit voltage and motor wiring before energizing. Apply the manual derating and reactor guidance for temperature, altitude and long cable runs.

Frequently Asked Questions

Can the inverter run a pump directly from solar panels?

Yes. The QB100-PV S2 is designed for PV-powered pumping. Confirm the PV string voltage remains inside the verified range for the selected 220V class · 3-phase 220V output model.

Can grid power or a generator be used as backup?

Backup input depends on the selected branch and wiring configuration. Do not connect sources simultaneously unless the selected model and protection arrangement explicitly support it.

How should the inverter power be selected?

Check the pump nameplate current, rated voltage, phase, motor type, head, flow and cable length. The selected inverter current must meet the motor requirement.

Does the system need batteries?

The standard solar-pumping architecture can operate directly from the PV array. Battery use is not required unless a separate project design specifies it.

Is remote monitoring standard?

Remote communication is optional or model-dependent. Confirm the required GPRS, 4G or Wi-Fi module before ordering.

Engineering selection & bulk orders

Send the nameplate. We size the drive.

Send the pump nameplate, PV module data, required head and flow, cable length and quantity. Our team will confirm the suitable model and project configuration.

Email Us
WhatsApp

Email: [email protected] · WhatsApp: +86 183 5724 1165

Talk to an engineerFACTORY-DIRECT · MON–SAT 8:30–17:30 (GMT+8)