IDEEI D3300 Closed-Loop Elevator Inverter 2.2-45kW

2.2kW3.7kW5.5kW7.5kW11kW15kW18.5kW22kW30kW37kW45kWD3300380VClosed LoopPMSMRS485
In Stock Price on Request MOQ 1 UNIT

IDEEI D3300 elevator inverter covers 2.2-45kW at 380-440V, with SVC/FVC control, PMSM and induction-motor support, elevator logic, RS485 and UPS rescue functions.

  • F012.2-45kW verified 380-440V model table
  • F02SVC and feedback vector control modes
  • F03Asynchronous motor and PMSM support
  • F04200% startup torque at 0Hz under FVC
  • F05Direct-travel ride and startup pre-torque functions
DOC DS-DESCSERIES ELEVATOR INVERTERREV 2026-A
IDEEI · Elevator Motion Control

IDEEI D3300 Closed-Loop Elevator Inverter 2.2-45kW

The D3300 is a high-performance elevator vector drive with a verified 380-440V model table from 2.2kW through 45kW. It combines motor-control functions with elevator-specific sequencing, protection, direct-travel and emergency-operation functions.

2.2-45kW380-440VSVC / FVCPMSM + induction

Key Features & Benefits

Closed-Loop Vector Control

Encoder feedback supports high low-speed precision and controlled torque for elevator motion.

Elevator Ride Functions

S-curve, pre-torque and direct-travel functions support smooth starting, travel and landing when correctly commissioned.

Brake & Contactor Logic

Elevator-specific outputs and protections coordinate the drive with the wider control and safety system.

Motor & Encoder Options

PMSM and asynchronous motor projects require the matching motor parameters, encoder and PG interface.

Verified Model Selection

The table separates verified published data from project-dependent choices. Match the product by electrical ratings and application conditions; do not select from the headline power value alone.

Model Motor power (kW) Input current (A) Output current (A)
D3300-2.2KW-4 2.2 6.5 5.1
D3300-3.7KW-4 3.7 10.5 9.0
D3300-5.5KW-4 5.5 14.8 13.0
D3300-7.5KW-4 7.5 20.5 18.0
D3300-11KW-4 11 29.0 27.0
D3300-15KW-4 15 36.0 33.0
D3300-18.5KW-4 18.5 41.0 39.0
D3300-22KW-4 22 49.5 48.0
D3300-30KW-4 30 62.0 60.0
D3300-37KW-4 37 77.0 75.0
D3300-45KW-4 45 93.0 91.0
Selection note: Select by rated motor current and elevator duty, then confirm encoder, PG card, braking components and rescue-power design.

Technical Specifications

Item Verified specification
Input voltage Three-phase 380-440V
Control modes SVC and FVC
Startup torque 180% at 0.5Hz SVC; 200% at 0Hz FVC
Speed range 1:100 SVC; 1:1000 FVC
Speed stability ±0.5% SVC; ±0.05% FVC
Overload 150% rated current for 60s; 180% for 1s
Motor support Asynchronous motor and PMSM
Communication RS485
Options / project configuration: External keypad, PG card, braking resistor/unit, I/O extension and emergency-power hardware depend on model and project requirements.

Typical Applications

Passenger elevators
Cargo elevators
Villa elevators
Hospital lifts
Elevator modernization
Control-panel and OEM projects

Information Required for Selection

  • Traction or door motor nameplate: power, voltage, current, frequency and motor type
  • Encoder type, signal format, resolution and required PG card for closed-loop systems
  • Elevator type, rated speed, load, travel height, floor count and duty cycle
  • Brake coil, braking resistor, UPS rescue supply and safety-chain arrangement
  • Control interface, I/O count, communication protocol and panel compatibility
  • Site temperature, altitude, cable length, quantity and destination

A dependable quotation requires the complete operating profile, not only the nominal power. IDEEI reviews voltage, current, source or motor data, duty, environment, required options and destination together so the final configuration, accessories, protection devices and commercial scope can be stated clearly.

Engineering & Installation Notes

The inverter or integrated controller is one part of the elevator control and safety system. Door circuits, mechanical brake, safety chain, final limits, rescue power and inspection controls remain system-level responsibilities. Commission motor data and encoder interfaces only with the car secured and qualified personnel present. Verify braking energy, resistor duty, contactor sequence and local elevator code before passenger service.

Installation and commissioning must be completed by qualified electrical personnel. Isolate all energy sources before wiring, verify terminal functions against the current manual, provide protective devices and grounding, and apply the published derating guidance for altitude, temperature, enclosure and cable length. Product-page data supports preliminary selection and does not replace project engineering or local code compliance.

Frequently Asked Questions

Can this drive control both PMSM and asynchronous motors?

Motor support depends on the selected D3300 control mode and hardware. Send the motor nameplate and encoder details so the correct model, PG card and tuning procedure can be confirmed.

What is the difference between open-loop and closed-loop control?

Open-loop vector control estimates motor operation without encoder feedback. Closed-loop vector control uses a compatible encoder and PG interface for higher low-speed and zero-speed performance.

Is UPS rescue operation included?

UPS or battery rescue functions are series- and project-dependent. The emergency power rating, wiring, travel logic, contactors and local safety requirements must be engineered as a complete system.

Can the inverter be selected only by motor kW?

No. Rated motor current, elevator load, speed, duty cycle, braking energy, motor type, encoder, cable length and ambient conditions all affect final selection.

What should be sent for a quotation?

Send the motor nameplate, elevator type, load, speed, travel height, floor count, encoder, brake arrangement, control-panel information, quantity and destination.

Engineering selection & bulk orders

Send the nameplate. We size the drive.

Send the required electrical and application data, quantity and destination. Our team will confirm the suitable model, options and quotation scope.

Request a Quote
Email Us
WhatsApp

Email: sales@ideeishop.com · WhatsApp: +86 183 5724 1165

Talk to an engineerFACTORY-DIRECT · MON–SAT 8:30–17:30 (GMT+8)

Related Models

( REL ) — ELEVATOR INVERTER
/01 IDEEI 1K+ Integrated Elevator Controller 2.2-55kW 2.2kW · 3.7kW · 5.5kW In StockRFQ
/02 IDEEI D3300-P Closed-Loop Elevator Inverter 3.7-37kW 3.7kW · 5.5kW · 7.5kW In StockRFQ
/03 IDEEI Z3300 Open-Loop Elevator Inverter 2.2-37kW 2.2kW · 3.7kW · 5.5kW In StockRFQ
/04 IDEEI Z3300-P Open-Loop Elevator Inverter 2.2-37kW 2.2kW · 3.7kW · 5.5kW In StockRFQ