IDEEI 11LIFT open-loop elevator inverter covers verified 220V and 380V branches with elevator motion functions, RS485, braking and UPS rescue support.
The 11LIFT platform supports open-loop elevator control together with elevator-specific brake, contactor, protection and rescue functions. Exact current rows are verified to 15kW at 380V; catalog branch ranges cover additional powers that require exact-order confirmation.
Sensorless vector control reduces feedback hardware for suitable asynchronous elevator applications.
Preset speeds and S-curve acceleration/deceleration support application-specific motion profiles.
Brake, contactor, overspeed, speed-deviation and motor protection functions support system integration.
RS485 and scalable I/O functions support control-panel and modernization projects where listed.
The table separates verified published data from project-dependent choices. Match the product by electrical ratings and application conditions; do not select from the headline power value alone.
| Published branch / model | Power (kW) | Input current (A) | Output current (A) | Data status |
|---|---|---|---|---|
| 11LIFT 2.2kW 380V | 2.2 | 6.5 | 5.1 | Manual verified |
| 11LIFT 3.7kW 380V | 3.7 | 10.5 | 9.0 | Manual verified |
| 11LIFT 5.5kW 380V | 5.5 | 14.8 | 13.0 | Manual verified |
| 11LIFT 7.5kW 380V | 7.5 | 20.5 | 18.0 | Manual verified |
| 11LIFT 11kW 380V | 11 | 29.0 | 27.0 | Manual verified |
| 11LIFT 15kW 380V | 15 | 36.0 | 33.0 | Manual verified |
| 11LIFT 18.5-37kW 380V branch | 18.5-37 | Confirm | Confirm | Catalog range; exact model required |
| 11LIFT 3.7-7.5kW 220V branch | 3.7-7.5 | Confirm | Confirm | Catalog range; exact model required |
| Item | Verified specification |
|---|---|
| Published catalog branches | AC 3PH 220-240V: 3.7-7.5kW; AC 3PH 380-480V: 3.7-37kW |
| Detailed manual voltage | Three-phase 380V, range 380-440V |
| Control modes | SVC and FVC |
| Startup torque | 180% at 0.5Hz SVC; 200% at 0Hz FVC |
| Communication | RS485 |
| Motor support | Asynchronous and PMSM with correct configuration |
| Emergency operation | 48V battery and UPS functions documented |
A dependable quotation requires the complete operating profile, not only the nominal power. IDEEI reviews voltage, current, source or motor data, duty, environment, required options and destination together so the final configuration, accessories, protection devices and commercial scope can be stated clearly.
The inverter or integrated controller is one part of the elevator control and safety system. Door circuits, mechanical brake, safety chain, final limits, rescue power and inspection controls remain system-level responsibilities. Commission motor data and encoder interfaces only with the car secured and qualified personnel present. Verify braking energy, resistor duty, contactor sequence and local elevator code before passenger service.
Installation and commissioning must be completed by qualified electrical personnel. Isolate all energy sources before wiring, verify terminal functions against the current manual, provide protective devices and grounding, and apply the published derating guidance for altitude, temperature, enclosure and cable length. Product-page data supports preliminary selection and does not replace project engineering or local code compliance.
Motor support depends on the selected 11LIFT Open-Loop control mode and hardware. Send the motor nameplate and encoder details so the correct model, PG card and tuning procedure can be confirmed.
Open-loop vector control estimates motor operation without encoder feedback. Closed-loop vector control uses a compatible encoder and PG interface for higher low-speed and zero-speed performance.
UPS or battery rescue functions are series- and project-dependent. The emergency power rating, wiring, travel logic, contactors and local safety requirements must be engineered as a complete system.
No. Rated motor current, elevator load, speed, duty cycle, braking energy, motor type, encoder, cable length and ambient conditions all affect final selection.
Send the motor nameplate, elevator type, load, speed, travel height, floor count, encoder, brake arrangement, control-panel information, quantity and destination.
Send the required electrical and application data, quantity and destination. Our team will confirm the suitable model, options and quotation scope.
Request a Quote
Email Us
WhatsApp
Email: sales@ideeishop.com · WhatsApp: +86 183 5724 1165
Questions about model selection, bulk pricing or shipping? Chat with us directly.
Start WhatsApp Chat →Questions about model selection, bulk pricing or shipping? Chat with us directly.