FÁBRICA ONLINE — HAIYAN, ZHEJIANG
SEG–SÁB 8:30–17:30 (GMT+8) [email protected] WA +86 183 5724 1165
Solicitar cotação→ Contato
Home/Products/Inversor para elevadores/Controlador Integrado para Elevadores IDEEI 1K+ 2,2-55kW
00 — INVERSOR PARA ELEVADORES

Controlador Integrado para Elevadores IDEEI 1K+ 2,2-55kW

2.2kW3.7kW5.5kW7.5kW11kW15kW18.5kW22kW30kW37kW45kW55kW1K+LX-D1K380VPMSMIntegrated Controller
In Stock Price on Request MOQ 1 UNIT

Controlador IDEEI para elevadores.

  • F01Integrated elevator logic and motor-drive control
  • F02PMSM gearless and asynchronous geared motor support
  • F03Direct-to-floor travel and anti-rollback functions
  • F04Eight floors standard and up to 16 with expansion I/O
  • F05Direct parallel control for two elevators
DOC DS-DESCSERIES INVERSOR PARA ELEVADORESREV 2026-A
IDEEI · Controle de Movimento para Elevadores

Controlador Integrado para Elevadores IDEEI 1K+ 2,2-55kW

O 1K+ / LX-D1K combina lógica de controle de elevador com um inversor CA para elevadores em malha fechada.

Faixa de produto 2,2-55kWAté 16 andaresPMSM + inductionTwo-elevator parallel

Principais características e benefícios

Integrated Control

Combines elevator motion drive and elevator logic to reduce separate control components.

Motor Flexibility

Supports PMSM gearless and asynchronous geared traction machines with correct encoder hardware.

Floor & Parallel Control

Eight-floor full collective is standard, with expansion to sixteen and duplex parallel control.

Commissioning Tools

Direct-travel, anti-rollback, I/O expansion and diagnostics support new and modernization projects.

Seleção verificada do modelo

A tabela separa dados publicados verificados de escolhas dependentes do projeto. Selecione o produto pelas classificações elétricas e condições de aplicação; não selecione apenas pelo valor de potência do título.

Model / range Voltage Motor power (kW) Input current (A) Output current (A)
D1K-4002-2.2KW 380-480V 2.2 6.5 5.1
D1K-4003-3.7KW 380-480V 3.7 10.5 9.0
D1K-4005-5.5KW 380-480V 5.5 14.8 13.0
D1K-4007-7.5KW 380-480V 7.5 20.5 18.0
D1K-4011-11KW 380-480V 11 29.0 27.0
D1K-4015-15KW 380-480V 15 36.0 33.0
D1K 220V branch 220-240V 2.2-7.5 See selected model See selected model
1K+ extended product range 380V 18.5-55 Confirm Confirm
Nota de seleção: Use the exact D1K rows for 2.2-15kW 380V and 2.2-7.5kW 220V. For 18.5-55kW, confirm the current production order code and electrical data before publishing an individual SKU.

Especificações técnicas

Item Especificação verificada
Elevator speed Up to 1.75m/s stated
Floor control 8 floors standard; expansion to 16
Motor support PMSM gearless and asynchronous geared
Group control Two-elevator parallel control
Communication CANbus and Modbus
Operating voltage range 323-528V AC for 380-480V class
Enclosure IP20 stated
Braking unit Built in on listed D1K models
Opções / configuração do projeto: Floor I/O expansion, encoder card, UPS arrangement, keypad, braking components and duplex-control configuration must be specified with the control panel.

Aplicações típicas

Passenger elevators
Cargo elevators
Villa elevators
Hospital lifts
Elevator modernization
Control-panel and OEM projects

Informações necessárias para seleção

  • Traction or door motor nameplate: power, voltage, current, frequency and motor type
  • Encoder type, signal format, resolution and required PG card for closed-loop systems
  • Elevator type, rated speed, load, travel height, floor count and duty cycle
  • Brake coil, braking resistor, UPS rescue supply and safety-chain arrangement
  • Control interface, I/O count, communication protocol and panel compatibility
  • Site temperature, altitude, cable length, quantity and destination

Uma cotação confiável requer o perfil operacional completo, não apenas a potência nominal. A IDEEI analisa tensão, corrente, dados de fonte ou motor, regime, ambiente, opções necessárias e destino em conjunto, para que a configuração final, acessórios, dispositivos de proteção e escopo comercial possam ser definidos claramente.

Notas de engenharia e instalação

The inverter or integrated controller is one part of the elevator control and safety system. Door circuits, mechanical brake, safety chain, final limits, rescue power and inspection controls remain system-level responsibilities. Commission motor data and encoder interfaces only with the car secured and qualified personnel present. Verify braking energy, resistor duty, contactor sequence and local elevator code before passenger service.

A instalação e o comissionamento devem ser realizados por pessoal elétrico qualificado. Isole todas as fontes de energia antes da fiação, verifique as funções dos terminais conforme o manual atual, forneça dispositivos de proteção e aterramento, e aplique as orientações de derating publicadas para altitude, temperatura, invólucro e comprimento de cabos. Os dados da página do produto auxiliam na seleção preliminar e não substituem a engenharia do projeto nem a conformidade com normas locais.

Perguntas frequentes

Can this drive control both PMSM and asynchronous motors?

Motor support depends on the selected 1K+ / LX-D1K control mode and hardware. Send the motor nameplate and encoder details so the correct model, PG card and tuning procedure can be confirmed.

What is the difference between open-loop and closed-loop control?

Open-loop vector control estimates motor operation without encoder feedback. Closed-loop vector control uses a compatible encoder and PG interface for higher low-speed and zero-speed performance.

Is UPS rescue operation included?

UPS or battery rescue functions are series- and project-dependent. The emergency power rating, wiring, travel logic, contactors and local safety requirements must be engineered as a complete system.

Can the inverter be selected only by motor kW?

No. Rated motor current, elevator load, speed, duty cycle, braking energy, motor type, encoder, cable length and ambient conditions all affect final selection.

What should be sent for a quotation?

Send the motor nameplate, elevator type, load, speed, travel height, floor count, encoder, brake arrangement, control-panel information, quantity and destination.

Seleção de engenharia e pedidos em volume

Envie a placa de identificação. Nós dimensionamos o inversor.

Envie os dados elétricos e de aplicação necessários, quantidade e destino. Nossa equipe confirmará o modelo adequado, opções e escopo da cotação.

Solicitar orçamento
Envie um e-mail
WhatsApp

Email: [email protected] · WhatsApp: +86 183 5724 1165

Talk to an engineerFACTORY-DIRECT · MON–SAT 8:30–17:30 (GMT+8)

Related Models

( REL ) — INVERSOR PARA ELEVADORES