00 — INVERSOR PARA BOMBAS SOLARES

IDEEI 118 Book Variador para bombas solares 0.4–500kW MPPT CA/CC

0.4kW0.75kW1.5kW2.2kW4kW5.5kW7.5kW11kW15kW18.5kW22kW30kW37kW45kW55kW75kW90kW110kW0.4–55kW 1PH 220–240V0.4–90kW 3PH 220–240V0.4–500kW 3PH 380–440V118 Series
In Stock Price on Request MOQ 1 UNIT
  • F01MPPT Solar Tracking: The controller adjusts pump speed as available PV power changes, supporting direct solar water pumping.
  • F02Pump-Oriented Control: Automatic operating logic and pump protection functions support unattended water-supply applications.
  • F03AC/DC Project Flexibility: PV input is the primary source; supported AC backup arrangements depend on the selected model and wiring.
  • F04Engineering Selection: Current, voltage, phase, motor type, PV string and cable length are checked together before ordering.
DOC DS-DESCSERIES INVERSOR PARA BOMBAS SOLARESREV 2026-A
IDEEI · Solar Pumping Control

IDEEI 118 Book Variador para bombas solares 0.4–500kW

La serie 118 combina un gabinete estilo libro que ahorra espacio con múltiples modos MPPT para proyectos de bombas monofásicas y trifásicas. El catálogo confirma ramas de 220–240V hasta 55/90kW y una rama de 380–440V hasta 500kW; la tabla detallada de corriente se limita a las filas verificadas del manual.

0.4–500kW catalog range220–240V / 380–440VMPPT above 99%RS485 interface

Características y beneficios clave

MPPT Solar Tracking

El controlador ajusta la velocidad de la bomba a medida que cambia la potencia FV disponible, permitiendo el bombeo solar directo de agua.

Pump-Oriented Control

La lógica de operación automática y las funciones de protección de la bomba permiten aplicaciones de suministro de agua desatendidas.

AC/DC Project Flexibility

La entrada FV es la fuente principal; las disposiciones de respaldo de CA admitidas dependen del modelo elegido y del cableado.

Engineering Selection

La corriente, la tensión, la fase, el tipo de motor, la cadena FV y la longitud del cable se verifican en conjunto antes de hacer el pedido.

Selección de modelos

La siguiente tabla mantiene visibles todas las ramas de potencia o modelos verificados. Elegí el inversor según la corriente nominal de la bomba, la tensión, la fase y las condiciones de aplicación, no solo por los kW.

Branch Pump power PV input Output Tensión FV recomendada Corriente nominal de salida
118-D3 0.75kW DC150–450V 3-phase 220–240VAC 360–430V 4A
118-D3 1.5kW DC150–450V 3-phase 220–240VAC 360–430V 7A
118-D3 2.2kW DC150–450V 3-phase 220–240VAC 360–430V 10A
118-D3 4kW DC150–450V 3-phase 220–240VAC 360–430V 16A
118-D3 5.5kW DC150–450V 3-phase 220–240VAC 360–430V 20A
118-D3 7.5kW DC150–450V 3-phase 220–240VAC 360–430V 30A
118-D3 11kW DC150–450V 3-phase 220–240VAC 360–430V 42A
118-SS2 0.75kW DC150–450V single-phase 220–240VAC 360–430V 7A
118-SS2 1.5kW DC150–450V single-phase 220–240VAC 360–430V 10A
118-SS2 2.2kW DC150–450V single-phase 220–240VAC 360–430V 16A
118-SS2 4kW DC150–450V single-phase 220–240VAC 360–430V 30A
118-SS2 5.5kW DC150–450V single-phase 220–240VAC 360–430V 42A
118-SS2 7.5kW DC150–450V single-phase 220–240VAC 360–430V 55A
118-SS2 11kW DC150–450V single-phase 220–240VAC 360–430V 80A
118-SS2 15kW DC150–450V single-phase 220–240VAC 360–430V 110A
118-D5 0.75kW DC250–900V 3-phase 380–460VAC 620–850V 3A
118-D5 1.5kW DC250–900V 3-phase 380–460VAC 620–850V 4A
118-D5 2.2kW DC250–900V 3-phase 380–460VAC 620–850V 6A
118-D5 4kW DC250–900V 3-phase 380–460VAC 620–850V 10A
118-D5 5.5kW DC250–900V 3-phase 380–460VAC 620–850V 13A
118-D5 7.5kW DC250–900V 3-phase 380–460VAC 620–850V 17A
118-D5 11kW DC250–900V 3-phase 380–460VAC 620–850V 25A
118-D5 15kW DC250–900V 3-phase 380–460VAC 620–850V 32A
118-D5 18.5kW DC250–900V 3-phase 380–460VAC 620–850V 38A
118-D5 22kW DC250–900V 3-phase 380–460VAC 620–850V 45A
118-D5 30kW DC250–900V 3-phase 380–460VAC 620–850V 60A
118-T3 37kW DC350–900V 3-phase 380–440VAC 620–850V 75A
118-T3 45kW DC350–900V 3-phase 380–440VAC 620–850V 90A
118-T3 55kW DC350–900V 3-phase 380–440VAC 620–850V 110A
118-T3 75kW DC350–900V 3-phase 380–440VAC 620–850V 150A
118-T3 90kW DC350–900V 3-phase 380–440VAC 620–850V 180A
118-T3 110kW DC350–900V 3-phase 380–440VAC 620–850V 210A
Nota de selección: Confirmá la corriente nominal de la bomba, la tensión, la fase y el tipo de motor. Para bombas sumergibles o cables largos de motor, puede requerirse la siguiente corriente nominal adecuada y un reactor de salida.

Especificaciones técnicas

Item Verified specification
Catalog power branches 1PH 220–240V: 0.4–55kW; 3PH 220–240V: 0.4–90kW; 3PH 380–440V: 0.4–500kW
Maximum PV input voltage Up to 900V DC
MPPT Multiple modes; catalog states above 99%
Isolation Aislamiento de CC y CA integrado
Communication Built-in RS485; GPRS connection supported by project configuration
Opciones / configuración del proyecto: El modo CA/CC personalizado y el control remoto GPRS requieren confirmación. El catálogo indica rangos de ramas pero no todos los códigos de pedido de alta potencia ni la corriente nominal; los modelos fuera de la tabla detallada del manual deben confirmarse antes de hacer el pedido.

Aplicaciones típicas

Urban water supply
Desert water management
Grassland animal husbandry
Aquaculture water supply
Agricultural irrigation
Remote-area pumping

Información necesaria para la selección del modelo

  • Potencia nominal de la bomba, tensión, fase y corriente a plena carga
  • Tipo de bomba y tipo de motor (inducción, PMSM o monofásico)
  • Altura, caudal y tiempo de operación diario requeridos
  • Voc, Vmp, potencia del módulo FV y disposición serie/paralelo planificada
  • Grid or generator backup requirement
  • Longitud del cable, altitud del sitio, temperatura ambiente y requisito de gabinete

Para una cotización confiable, también confirmá la altitud de instalación, la temperatura ambiente, el requisito de gabinete, el cronograma de operación diario, las condiciones de la fuente de agua y si se requiere respaldo de red o generador. Estos detalles afectan la reducción de potencia, la selección del cable, los dispositivos de protección y el diseño final del sistema CA/CC.

Notas de instalación y reducción de potencia

La instalación y la puesta en marcha deben ser realizadas por personal eléctrico calificado. Verificá la polaridad, la puesta a tierra, los dispositivos de protección, la tensión de circuito abierto FV y el cableado del motor antes de energizar. Aplicá la guía de reducción de potencia y reactor del manual para temperatura, altitud y tramos largos de cable.

Preguntas frecuentes

¿El inversor puede hacer funcionar una bomba directamente desde paneles solares?

Sí. La Serie 118 está diseñada para bombeo con energía FV. Confirmá que la tensión de la cadena FV se mantenga dentro del rango verificado para el modelo elegido de 220V y 380V.

¿Se puede usar la red eléctrica o un generador como respaldo?

La entrada de respaldo depende de la rama elegida y de la configuración del cableado. No conectes las fuentes simultáneamente a menos que el modelo elegido y la disposición de protección lo admitan explícitamente.

¿Cómo se debe seleccionar la potencia del inversor?

Revisá la corriente de placa de la bomba, la tensión nominal, la fase, el tipo de motor, la altura, el caudal y la longitud del cable. La corriente del inversor elegido debe satisfacer el requerimiento del motor.

¿El sistema necesita baterías?

La arquitectura estándar de bombeo solar puede operar directamente desde el arreglo FV. No se requieren baterías a menos que un diseño de proyecto separado lo especifique.

¿El monitoreo remoto es estándar?

La comunicación remota es opcional o depende del modelo. Confirmá el módulo GPRS, 4G o Wi-Fi requerido antes de hacer el pedido.

Selección de ingeniería y pedidos en volumen

Envianos la placa. Dimensionamos el variador.

Enviá la placa de la bomba, los datos del módulo FV, la altura y el caudal requeridos, la longitud del cable y la cantidad. Nuestro equipo confirmará el modelo adecuado y la configuración del proyecto.

Email Us
WhatsApp

Email: [email protected] · WhatsApp: +86 183 5724 1165

Talk to an engineerFACTORY-DIRECT · MON–SAT 8:30–17:30 (GMT+8)

Related Models

( REL ) — INVERSOR PARA BOMBAS SOLARES