Inversor para bombas solares IDEEI 118 Book 0,4–500kW com invólucro compacto e múltiplos modos MPPT para projetos monofásicos e trifásicos.
A série 118 combina um invólucro compacto estilo livro com múltiplos modos MPPT para projetos de bombas monofásicas e trifásicas. O catálogo confirma ramificações 220–240V até 55/90kW e uma ramificação 380–440V até 500kW; a tabela detalhada de corrente permanece limitada às linhas verificadas do manual.
The controller adjusts pump speed as available PV power changes, supporting direct solar water pumping.
Automatic operating logic and pump protection functions support unattended water-supply applications.
PV input is the primary source; supported AC backup arrangements depend on the selected model and wiring.
Current, voltage, phase, motor type, PV string and cable length are checked together before ordering.
The table below keeps every verified power or model branch visible. Match the inverter by pump rated current, voltage, phase and application conditions—not by kW alone.
| Branch | Pump power | PV input | Output | Recommended PV voltage | Rated output current |
|---|---|---|---|---|---|
| 118-D3 | 0.75kW | DC150–450V | 3-phase 220–240VAC | 360–430V | 4A |
| 118-D3 | 1.5kW | DC150–450V | 3-phase 220–240VAC | 360–430V | 7A |
| 118-D3 | 2.2kW | DC150–450V | 3-phase 220–240VAC | 360–430V | 10A |
| 118-D3 | 4kW | DC150–450V | 3-phase 220–240VAC | 360–430V | 16A |
| 118-D3 | 5.5kW | DC150–450V | 3-phase 220–240VAC | 360–430V | 20A |
| 118-D3 | 7.5kW | DC150–450V | 3-phase 220–240VAC | 360–430V | 30A |
| 118-D3 | 11kW | DC150–450V | 3-phase 220–240VAC | 360–430V | 42A |
| 118-SS2 | 0.75kW | DC150–450V | single-phase 220–240VAC | 360–430V | 7A |
| 118-SS2 | 1.5kW | DC150–450V | single-phase 220–240VAC | 360–430V | 10A |
| 118-SS2 | 2.2kW | DC150–450V | single-phase 220–240VAC | 360–430V | 16A |
| 118-SS2 | 4kW | DC150–450V | single-phase 220–240VAC | 360–430V | 30A |
| 118-SS2 | 5.5kW | DC150–450V | single-phase 220–240VAC | 360–430V | 42A |
| 118-SS2 | 7.5kW | DC150–450V | single-phase 220–240VAC | 360–430V | 55A |
| 118-SS2 | 11kW | DC150–450V | single-phase 220–240VAC | 360–430V | 80A |
| 118-SS2 | 15kW | DC150–450V | single-phase 220–240VAC | 360–430V | 110A |
| 118-D5 | 0.75kW | DC250–900V | 3-phase 380–460VAC | 620–850V | 3A |
| 118-D5 | 1.5kW | DC250–900V | 3-phase 380–460VAC | 620–850V | 4A |
| 118-D5 | 2.2kW | DC250–900V | 3-phase 380–460VAC | 620–850V | 6A |
| 118-D5 | 4kW | DC250–900V | 3-phase 380–460VAC | 620–850V | 10A |
| 118-D5 | 5.5kW | DC250–900V | 3-phase 380–460VAC | 620–850V | 13A |
| 118-D5 | 7.5kW | DC250–900V | 3-phase 380–460VAC | 620–850V | 17A |
| 118-D5 | 11kW | DC250–900V | 3-phase 380–460VAC | 620–850V | 25A |
| 118-D5 | 15kW | DC250–900V | 3-phase 380–460VAC | 620–850V | 32A |
| 118-D5 | 18.5kW | DC250–900V | 3-phase 380–460VAC | 620–850V | 38A |
| 118-D5 | 22kW | DC250–900V | 3-phase 380–460VAC | 620–850V | 45A |
| 118-D5 | 30kW | DC250–900V | 3-phase 380–460VAC | 620–850V | 60A |
| 118-T3 | 37kW | DC350–900V | 3-phase 380–440VAC | 620–850V | 75A |
| 118-T3 | 45kW | DC350–900V | 3-phase 380–440VAC | 620–850V | 90A |
| 118-T3 | 55kW | DC350–900V | 3-phase 380–440VAC | 620–850V | 110A |
| 118-T3 | 75kW | DC350–900V | 3-phase 380–440VAC | 620–850V | 150A |
| 118-T3 | 90kW | DC350–900V | 3-phase 380–440VAC | 620–850V | 180A |
| 118-T3 | 110kW | DC350–900V | 3-phase 380–440VAC | 620–850V | 210A |
| Item | Especificação verificada |
|---|---|
| Catalog power branches | 1PH 220–240V: 0.4–55kW; 3PH 220–240V: 0.4–90kW; 3PH 380–440V: 0.4–500kW |
| Maximum PV input voltage | Up to 900V DC |
| MPPT | Multiple modes; catalog states above 99% |
| Isolation | Built-in DC and AC isolation |
| Communication | Built-in RS485; GPRS connection supported by project configuration |
For a dependable quotation, also confirm the installation altitude, ambient temperature, enclosure requirement, daily operating schedule, water-source conditions and whether utility or generator backup is required. These details affect derating, cable selection, protection devices and the final AC/DC system design.
Installation and commissioning must be completed by qualified electrical personnel. Verify polarity, grounding, protective devices, PV open-circuit voltage and motor wiring before energizing. Apply the manual derating and reactor guidance for temperature, altitude and long cable runs.
Yes. The 118 Series is designed for PV-powered pumping. Confirm the PV string voltage remains inside the verified range for the selected 220V and 380V classes model.
Backup input depends on the selected branch and wiring configuration. Do not connect sources simultaneously unless the selected model and protection arrangement explicitly support it.
Check the pump nameplate current, rated voltage, phase, motor type, head, flow and cable length. The selected inverter current must meet the motor requirement.
The standard solar-pumping architecture can operate directly from the PV array. Battery use is not required unless a separate project design specifies it.
Remote communication is optional or model-dependent. Confirm the required GPRS, 4G or Wi-Fi module before ordering.
Send the pump nameplate, PV module data, required head and flow, cable length and quantity. Our team will confirm the suitable model and project configuration.
Email: [email protected] · WhatsApp: +86 183 5724 1165
Inversor Solar para Bombeamento QB100-PV Carcaça de Ferro Branca 45-280kW
45kW · 55kW · 75kW
In StockRFQ
Inversor Solar para Bombeamento QB100-PV Carcaça de Plástico Branca 0,4-37kW
0.4kW · 0.75kW · 1.5kW
In StockRFQ
IDEEI S81 Inversor de Frequência Híbrido Solar para Bombas 0,75–200kW AC/DC
75–200 kW · S81 D3 · S81 D5
In StockRFQ
IDEEI S80 Inversor de Frequência Solar para Bombas 0,75–200kW MPPT VFD
75–200 kW · S80 D3 · S80 D5
In StockRFQ