FÁBRICA EN LÍNEA — HAIYAN, ZHEJIANG
LUN–SÁB 8:30–17:30 (GMT+8) [email protected] WA +86 183 5724 1165
Solicitar cotización→ Contacto
Home/Products/Inversor para ascensores/IDEEI 1K+ Controlador integrado para ascensores 2.2-55kW
00 — INVERSOR PARA ASCENSORES

IDEEI 1K+ Controlador integrado para ascensores 2.2-55kW

2.2kW3.7kW5.5kW7.5kW11kW15kW18.5kW22kW30kW37kW45kW55kW1K+LX-D1K380VPMSMIntegrated Controller
In Stock Price on Request MOQ 1 UNIT
  • F01Integrated elevator logic and motor-drive control
  • F02PMSM gearless and asynchronous geared motor support
  • F03Direct-to-floor travel and anti-rollback functions
  • F04Eight floors standard and up to 16 with expansion I/O
  • F05Direct parallel control for two elevators
DOC DS-DESCSERIES INVERSOR PARA ASCENSORESREV 2026-A
IDEEI · Elevator Motion Control

IDEEI 1K+ Controlador integrado para ascensores 2.2-55kW

El 1K+ / LX-D1K combina la lógica de control del ascensor con un variador CA de lazo cerrado para ascensores. El folleto D1K suministrado ofrece modelos exactos de bastidor pequeño, mientras la definición de producto aprobada existente extiende el rango de la página a 55kW. Los códigos de pedido extendidos y las corrientes siguen siendo ítems de confirmación.

2.2-55kW product rangeUp to 16 floorsPMSM + inductionTwo-elevator parallel

Características y beneficios clave

Control integrado

Combina el variador de movimiento del ascensor y la lógica del ascensor para reducir componentes de control separados.

Flexibilidad de motor

Admite máquinas de tracción PMSM sin engranajes y asíncronas con engranajes, con el hardware de encoder correcto.

Control de pisos y en paralelo

El colectivo total de ocho pisos es estándar, con expansión a dieciséis y control en paralelo dúplex.

Herramientas de puesta en marcha

El viaje directo, anti-retroceso, expansión de E/S y diagnósticos admiten proyectos nuevos y de modernización.

Selección de modelos verificados

The table separates verified published data from project-dependent choices. Match the product by electrical ratings and application conditions; do not select from the headline power value alone.

Model / range Voltage Motor power (kW) Input current (A) Output current (A)
D1K-4002-2.2KW 380-480V 2.2 6.5 5.1
D1K-4003-3.7KW 380-480V 3.7 10.5 9.0
D1K-4005-5.5KW 380-480V 5.5 14.8 13.0
D1K-4007-7.5KW 380-480V 7.5 20.5 18.0
D1K-4011-11KW 380-480V 11 29.0 27.0
D1K-4015-15KW 380-480V 15 36.0 33.0
D1K 220V branch 220-240V 2.2-7.5 See selected model See selected model
1K+ extended product range 380V 18.5-55 Confirm Confirm
Selection note: Use the exact D1K rows for 2.2-15kW 380V and 2.2-7.5kW 220V. For 18.5-55kW, confirm the current production order code and electrical data before publishing an individual SKU.

Especificaciones técnicas

Item Verified specification
Elevator speed Up to 1.75m/s stated
Floor control 8 floors standard; expansion to 16
Motor support PMSM gearless and asynchronous geared
Group control Two-elevator parallel control
Communication CANbus and Modbus
Operating voltage range 323-528V AC for 380-480V class
Enclosure IP20 stated
Braking unit Built in on listed D1K models
Options / project configuration: Floor I/O expansion, encoder card, UPS arrangement, keypad, braking components and duplex-control configuration must be specified with the control panel.

Aplicaciones típicas

Passenger elevators
Cargo elevators
Villa elevators
Hospital lifts
Elevator modernization
Control-panel and OEM projects

Información necesaria para la selección

  • Traction or door motor nameplate: power, voltage, current, frequency and motor type
  • Encoder type, signal format, resolution and required PG card for closed-loop systems
  • Elevator type, rated speed, load, travel height, floor count and duty cycle
  • Brake coil, braking resistor, UPS rescue supply and safety-chain arrangement
  • Control interface, I/O count, communication protocol and panel compatibility
  • Site temperature, altitude, cable length, quantity and destination

A dependable quotation requires the complete operating profile, not only the nominal power. IDEEI reviews voltage, current, source or motor data, duty, environment, required options and destination together so the final configuration, accessories, protection devices and commercial scope can be stated clearly.

Notas de ingeniería e instalación

The inverter or integrated controller is one part of the elevator control and safety system. Door circuits, mechanical brake, safety chain, final limits, rescue power and inspection controls remain system-level responsibilities. Commission motor data and encoder interfaces only with the car secured and qualified personnel present. Verify braking energy, resistor duty, contactor sequence and local elevator code before passenger service.

Installation and commissioning must be completed by qualified electrical personnel. Isolate all energy sources before wiring, verify terminal functions against the current manual, provide protective devices and grounding, and apply the published derating guidance for altitude, temperature, enclosure and cable length. Product-page data supports preliminary selection and does not replace project engineering or local code compliance.

Preguntas frecuentes

Can this drive control both PMSM and asynchronous motors?

Motor support depends on the selected 1K+ / LX-D1K control mode and hardware. Send the motor nameplate and encoder details so the correct model, PG card and tuning procedure can be confirmed.

What is the difference between open-loop and closed-loop control?

Open-loop vector control estimates motor operation without encoder feedback. Closed-loop vector control uses a compatible encoder and PG interface for higher low-speed and zero-speed performance.

Is UPS rescue operation included?

UPS or battery rescue functions are series- and project-dependent. The emergency power rating, wiring, travel logic, contactors and local safety requirements must be engineered as a complete system.

Can the inverter be selected only by motor kW?

No. Rated motor current, elevator load, speed, duty cycle, braking energy, motor type, encoder, cable length and ambient conditions all affect final selection.

What should be sent for a quotation?

Send the motor nameplate, elevator type, load, speed, travel height, floor count, encoder, brake arrangement, control-panel information, quantity and destination.

Selección de ingeniería y pedidos en volumen

Envianos la placa. Dimensionamos el variador.

Send the required electrical and application data, quantity and destination. Our team will confirm the suitable model, options and quotation scope.

Pedir cotización
Email Us
WhatsApp

Email: [email protected] · WhatsApp: +86 183 5724 1165

Talk to an engineerFACTORY-DIRECT · MON–SAT 8:30–17:30 (GMT+8)

Related Models

( REL ) — INVERSOR PARA ASCENSORES