Inversor para bombas solares IDEEI 11PV MPPT com suporte a motores AM/PMSM e funções remotas opcionais.
O 11PV está posicionado no catálogo de produtos aprovado como um inversor fotovoltaico para bombas com controle MPPT, cobrindo 2,2–37kW com opções CA/CC.
O catálogo indica operação automática de partida e repouso para condições solares variáveis.
Rastreamento do ponto de máxima potência indicado até ou acima de 99%, depending on the named series page.
O catálogo indica suporte para motores de bomba AM e PMSM with the correct configuration.
Funções Wi-Fi ou GPRS são opcionais onde indicadas in the series catalog.
The table below keeps every verified power or model branch visible. Match the inverter by pump rated current, voltage, phase and application conditions—not by kW alone.
| Ramificação do catálogo | Faixa de potência | Fase de saída | Classe de tensão | Código do pedido |
|---|---|---|---|---|
| CA 1F 220–240V | 0.4–55kW | Monofásico | 220–240V | Confirme o modelo exato do pedido |
| CA 3F 220–240V | 0.4–90kW | Trifásico | 220–240V | Confirme o modelo exato do pedido |
| CA 3F 380–440V | 0.4–200kW | Trifásico | 380–440V | Confirme o modelo exato do pedido |
| Item | Especificação verificada |
|---|---|
| Catalog range | 0.4–200kW |
| Voltage branches | 220–240V and 380–440V |
| MPPT efficiency | 99% |
| Motor support | AM and PMSM pumps |
| Operation | Automatic sunrise run and sleep/wake |
For a dependable quotation, also confirm the installation altitude, ambient temperature, enclosure requirement, daily operating schedule, water-source conditions and whether utility or generator backup is required. These details affect derating, cable selection, protection devices and the final AC/DC system design.
Installation and commissioning must be completed by qualified electrical personnel. Verify polarity, grounding, protective devices, PV open-circuit voltage and motor wiring before energizing. Apply the manual derating and reactor guidance for temperature, altitude and long cable runs.
Yes. The 11PV is designed for PV-powered pumping. Confirm the PV string voltage remains inside the verified range for the selected 220V and 380V classes model.
Backup input depends on the selected branch and wiring configuration. Do not connect sources simultaneously unless the selected model and protection arrangement explicitly support it.
Check the pump nameplate current, rated voltage, phase, motor type, head, flow and cable length. The selected inverter current must meet the motor requirement.
The standard solar-pumping architecture can operate directly from the PV array. Battery use is not required unless a separate project design specifies it.
Remote communication is optional or model-dependent. Confirm the required GPRS, 4G or Wi-Fi module before ordering.
Send the pump nameplate, PV module data, required head and flow, cable length and quantity. Our team will confirm the suitable model and project configuration.
Email: [email protected] · WhatsApp: +86 183 5724 1165
Inversor Solar para Bombeamento QB100-PV Carcaça de Ferro Branca 45-280kW
45kW · 55kW · 75kW
In StockRFQ
Inversor Solar para Bombeamento QB100-PV Carcaça de Plástico Branca 0,4-37kW
0.4kW · 0.75kW · 1.5kW
In StockRFQ
IDEEI S81 Inversor de Frequência Híbrido Solar para Bombas 0,75–200kW AC/DC
75–200 kW · S81 D3 · S81 D5
In StockRFQ
IDEEI S80 Inversor de Frequência Solar para Bombas 0,75–200kW MPPT VFD
75–200 kW · S80 D3 · S80 D5
In StockRFQ
Dúvidas sobre seleção, preços por volume ou envio? Fale diretamente conosco.
Iniciar conversa no WhatsApp →Questions about model selection, bulk pricing or shipping? Chat with us directly.
Start WhatsApp Chat →