FÁBRICA EN LÍNEA — HAIYAN, ZHEJIANG
LUN–SÁB 8:30–17:30 (GMT+8) [email protected] WA +86 183 5724 1165
Solicitar cotización→ Contacto
Home/Products/Controlador para montacargas de construcción/IDEEI S3300 Controlador todo en uno para montacargas de construcción 0.75-90kW
00 — CONTROLADOR PARA MONTACARGAS DE CONSTRUCCIóN

IDEEI S3300 Controlador todo en uno para montacargas de construcción 0.75-90kW

0.75kW1.5kW2.2kW4kW5.5kW7.5kW11kW15kW18.5kW22kW30kW37kW45kW55kW75kW90kWS3300380VConstruction Hoist
In Stock Price on Request MOQ 1 UNIT
  • F01Integrated drive and construction-hoist logic
  • F02Lifting-weight limiter and braking-unit integration
  • F03Voice fault and command prompts
  • F04Light-load high-speed function
  • F05Redundant brake-control design
DOC DS-DESCSERIES CONTROLADOR PARA MONTACARGAS DE CONSTRUCCIóNREV 2026-A
IDEEI · Elevator Motion Control

IDEEI S3300 Controlador todo en uno para montacargas de construcción 0.75-90kW

El controlador todo en uno S3300 integra variador, lógica, limitador de peso de elevación y funciones de frenado para sistemas de montacargas de construcción. Su tabla de variadores S3300 380V subyacente cubre de 0.75kW a 90kW.

Plataforma de variadores 0.75-90kW380VConstruction hoistBrake control

Características y beneficios clave

Control vectorial de lazo cerrado

La realimentación del encoder permite alta precisión a baja velocidad y torque controlado para el movimiento del ascensor.

Funciones de viaje del ascensor

Las funciones de curva S, pre-torque y viaje directo permiten arranques suaves, viaje y nivelación cuando están bien comisionadas.

Lógica de freno y contactor

Las salidas y protecciones específicas del ascensor coordinan el variador con el sistema de control y seguridad.

Opciones de motor y encoder

Los proyectos con motores PMSM y asíncronos requieren los parámetros del motor, el encoder y la interfaz PG correspondientes.

Selección de modelos verificados

The table separates verified published data from project-dependent choices. Match the product by electrical ratings and application conditions; do not select from the headline power value alone.

Drive model Motor power (kW) Input current (A) Output current (A)
S3300-0R7G-4 0.75 3.4 2.1
S3300-1R5G-4 1.5 5.0 3.8
S3300-2R2G-4 2.2 5.8 5.1
S3300-004G-4 4 10.5 9
S3300-5R5G-4 5.5 14.6 13
S3300-7R5G-4 7.5 20.5 17
S3300-011G-4 11 26 25
S3300-015G-4 15 35 32
S3300-018G-4 18.5 38.5 37
S3300-022G-4 22 46.5 45
S3300-030G-4 30 62 60
S3300-037G-4 37 76 75
S3300-045G-4 45 92 91
S3300-055G-4 55 113 112
S3300-075G-4 75 157 150
S3300-090G-4 90 180 176
Selection note: The model table verifies the S3300 drive platform. Confirm the final cabinet, logic board, limiter, sensors, braking hardware and site wiring for the selected construction-hoist solution.

Especificaciones técnicas

Item Verified specification
Input class Three-phase 380V
Output frequency 0-150Hz
Control modes V/F, open-loop vector and closed-loop vector
Startup torque 150% at 0.5Hz V/F; 200% at 0.5Hz open loop; 200% at 0Hz closed loop
Speed range 1:100 open loop; 1:1000 closed loop
Overload 150% for 60s; 180% for 3s
Model range 0.75-90kW verified in drive table
Options / project configuration: Voice module, load limiter, encoder, soft-limit sensors, braking components, status panel and enclosure are project-dependent.

Aplicaciones típicas

Construction material hoists
Building-site personnel hoists
Construction elevator modernization
Twin-cage hoist panels
Rental fleet refurbishment
Hoist-control OEM projects

Información necesaria para la selección

  • Traction or door motor nameplate: power, voltage, current, frequency and motor type
  • Encoder type, signal format, resolution and required PG card for closed-loop systems
  • Elevator type, rated speed, load, travel height, floor count and duty cycle
  • Brake coil, braking resistor, UPS rescue supply and safety-chain arrangement
  • Control interface, I/O count, communication protocol and panel compatibility
  • Site temperature, altitude, cable length, quantity and destination

A dependable quotation requires the complete operating profile, not only the nominal power. IDEEI reviews voltage, current, source or motor data, duty, environment, required options and destination together so the final configuration, accessories, protection devices and commercial scope can be stated clearly.

Notas de ingeniería e instalación

The inverter or integrated controller is one part of the elevator control and safety system. Door circuits, mechanical brake, safety chain, final limits, rescue power and inspection controls remain system-level responsibilities. Commission motor data and encoder interfaces only with the car secured and qualified personnel present. Verify braking energy, resistor duty, contactor sequence and local elevator code before passenger service.

Installation and commissioning must be completed by qualified electrical personnel. Isolate all energy sources before wiring, verify terminal functions against the current manual, provide protective devices and grounding, and apply the published derating guidance for altitude, temperature, enclosure and cable length. Product-page data supports preliminary selection and does not replace project engineering or local code compliance.

Preguntas frecuentes

Can this drive control both PMSM and asynchronous motors?

Motor support depends on the selected S3300 all-in-one control mode and hardware. Send the motor nameplate and encoder details so the correct model, PG card and tuning procedure can be confirmed.

What is the difference between open-loop and closed-loop control?

Open-loop vector control estimates motor operation without encoder feedback. Closed-loop vector control uses a compatible encoder and PG interface for higher low-speed and zero-speed performance.

Is UPS rescue operation included?

UPS or battery rescue functions are series- and project-dependent. The emergency power rating, wiring, travel logic, contactors and local safety requirements must be engineered as a complete system.

Can the inverter be selected only by motor kW?

No. Rated motor current, elevator load, speed, duty cycle, braking energy, motor type, encoder, cable length and ambient conditions all affect final selection.

What should be sent for a quotation?

Send the motor nameplate, elevator type, load, speed, travel height, floor count, encoder, brake arrangement, control-panel information, quantity and destination.

Selección de ingeniería y pedidos en volumen

Envianos la placa. Dimensionamos el variador.

Send the required electrical and application data, quantity and destination. Our team will confirm the suitable model, options and quotation scope.

Pedir cotización
Email Us
WhatsApp

Email: [email protected] · WhatsApp: +86 183 5724 1165

Talk to an engineerFACTORY-DIRECT · MON–SAT 8:30–17:30 (GMT+8)