FÁBRICA ONLINE — HAIYAN, ZHEJIANG
SEG–SÁB 8:30–17:30 (GMT+8) [email protected] WA +86 183 5724 1165
Solicitar cotação→ Contato
Home/Products/Inversor para bombas solares/Inversor para Bombas Solares IDEEI S319 0,4–315kW MPPT CA/CC
00 — INVERSOR PARA BOMBAS SOLARES

Inversor para Bombas Solares IDEEI S319 0,4–315kW MPPT CA/CC

S319 Series0.4–315kW220–240V380–440V1 Phase3 PhaseMPPTAC/DC
In Stock Price on Request MOQ 1 UNIT

Inversor para bombas solares IDEEI S319 0,4–315kW com controle MPPT para aplicações fotovoltaicas de bombeamento d'água.

  • F01Automatic Start & Sleep: Starts and sleeps automatically according to solar conditions.
  • F0299% MPPT: Maximum-power-point tracking is stated up to 99%.
  • F03Sensorless Dry-Run Protection: The catalog lists waterless protection without sensors.
  • F04Remote Options: Wi-Fi and GPRS modules are optional; timing is also optional.
  • F05AC/DC Operation: The catalog states simultaneous AC/DC access and seamless switching.
DOC DS-DESCSERIES INVERSOR PARA BOMBAS SOLARESREV 2026-A
IDEEI · Controle de Bombeamento Solar

Inversor para Bombas Solares IDEEI S319 0,4–315kW MPPT CA/CC

A série S319 foi projetada para aplicações fotovoltaicas de bombeamento d’água de 0,4–315kW. O catálogo aprovado confirma as ramificações de potência e tensão abaixo; códigos SKU exatos e classificações de corrente permanecem dependentes da seleção.

0.4–315kW220–240V / 380–440VMPPT 99%Operação CA/CC

Principais características e benefícios

Partida e repouso automáticos

Starts and sleeps automatically according to solar conditions.

MPPT 99%

Maximum-power-point tracking is stated up to 99%.

Sensorless Dry-Run Protection

The catalog lists waterless protection without sensors.

Remote Options

Wi-Fi and GPRS modules are optional; timing is also optional.

Model Selection

The table below keeps every verified power or model branch visible. Match the inverter by pump rated current, voltage, phase and application conditions—not by kW alone.

Catalog branch Power range Output phase Voltage class Order code
AC 1PH 220–240V 0.4–7.5kW Single phase 220–240V Confirm exact order model
AC 3PH 220–240V 0.4–15kW Three phase 220–240V Confirm exact order model
AC 3PH 380–440V 0.4–315kW Three phase 380–440V Confirm exact order model
Nota de seleção: The catalog publishes power ranges by voltage and phase but does not list every discrete order code. Confirm the exact model from the pump current, voltage, motor type and PV string.

Especificações técnicas

Item Especificação verificada
Catalog power branches AC 1PH 220–240V: 0.4–7.5kW; AC 3PH 220–240V: 0.4–15kW; AC 3PH 380–440V: 0.4–315kW
Opções / configuração do projeto: Any feature described as optional or customized—including Wi-Fi, GPRS, timer or AC/DC mode—must be confirmed for the selected order model.

Aplicações típicas

Urban water supply
Desert water management
Grassland animal husbandry
Aquaculture water supply
Agricultural irrigation
Remote-area pumping

Information Required for Model Selection

  • Pump rated power, voltage, phase and full-load current
  • Pump type and motor type (induction, PMSM or single-phase)
  • Required head, flow and daily operating time
  • PV module Voc, Vmp, power and planned series/parallel layout
  • Grid or generator backup requirement
  • Cable length, site altitude, ambient temperature and enclosure requirement

For a dependable quotation, also confirm the installation altitude, ambient temperature, enclosure requirement, daily operating schedule, water-source conditions and whether utility or generator backup is required. These details affect derating, cable selection, protection devices and the final AC/DC system design.

Installation & Derating Notes

Installation and commissioning must be completed by qualified electrical personnel. Verify polarity, grounding, protective devices, PV open-circuit voltage and motor wiring before energizing. Apply the manual derating and reactor guidance for temperature, altitude and long cable runs.

Perguntas frequentes

Can the inverter run a pump directly from solar panels?

Yes. The S319 Series is designed for PV-powered pumping. Confirm the PV string voltage remains inside the verified range for the selected 220–240V and 380–440V branches model.

Can grid power or a generator be used as backup?

Backup input depends on the selected branch and wiring configuration. Do not connect sources simultaneously unless the selected model and protection arrangement explicitly support it.

How should the inverter power be selected?

Check the pump nameplate current, rated voltage, phase, motor type, head, flow and cable length. The selected inverter current must meet the motor requirement.

Does the system need batteries?

The standard solar-pumping architecture can operate directly from the PV array. Battery use is not required unless a separate project design specifies it.

Is remote monitoring standard?

Remote communication is optional or model-dependent. Confirm the required GPRS, 4G or Wi-Fi module before ordering.

Seleção de engenharia e pedidos em volume

Envie a placa de identificação. Nós dimensionamos o inversor.

Send the pump nameplate, PV module data, required head and flow, cable length and quantity. Our team will confirm the suitable model and project configuration.

Envie um e-mail
WhatsApp

Email: [email protected] · WhatsApp: +86 183 5724 1165

Talk to an engineerFACTORY-DIRECT · MON–SAT 8:30–17:30 (GMT+8)