المصنع متصل — هايان، تشجيانغ
الاثنين–السبت 8:30–17:30 (GMT+8) [email protected] WA +86 183 5724 1165
اطلب عرض سعر→ اتصل بنا
Home/Products/وحدة تحكم رافعات البناء/IDEEI S3300 وحدة تحكم رافعة بناء متكاملة 0.75-90kW
00 — وحدة تحكم رافعات البناء

IDEEI S3300 وحدة تحكم رافعة بناء متكاملة 0.75-90kW

0.75kW1.5kW2.2kW4kW5.5kW7.5kW11kW15kW18.5kW22kW30kW37kW45kW55kW75kW90kWS3300380VConstruction Hoist
In Stock Price on Request MOQ 1 UNIT

IDEEI S3300 هي وحدة تحكم رافعة بناء متكاملة بقدرة 0.75-90kW.

  • F01Integrated drive and construction-hoist logic
  • F02Lifting-weight limiter and braking-unit integration
  • F03Voice fault and command prompts
  • F04Light-load high-speed function
  • F05Redundant brake-control design
DOC DS-DESCSERIES وحدة تحكم رافعات البناءREV 2026-A
IDEEI · التحكم في حركة المصاعد

IDEEI S3300 وحدة تحكم رافعة بناء متكاملة 0.75-90kW

The S3300 all-in-one controller integrates drive, logic, lifting-weight limiter and braking functions for construction-hoist systems. Its underlying 380V S3300 drive table covers 0.75kW through 90kW.

0.75-90kW drive platform380Vرافعة بناءالتحكم في الفرامل

المزايا والفوائد الرئيسية

التحكم المتجه بالحلقة المغلقة

Encoder feedback supports high low-speed precision and controlled torque for elevator motion.

وظائف ركوب المصعد

S-curve, pre-torque and direct-travel functions support smooth starting, travel and landing when correctly commissioned.

منطق الفرامل والموصل

Elevator-specific outputs and protections coordinate the drive with the wider control and safety system.

خيارات المحرك والمشفر

PMSM and asynchronous motor projects require the matching motor parameters, encoder and PG interface.

Verified Model Selection

The table separates verified published data from project-dependent choices. Match the product by electrical ratings and application conditions; do not select from the headline power value alone.

Drive model Motor power (kW) تيار الإدخال (A) Output current (A)
S3300-0R7G-4 0.75 3.4 2.1
S3300-1R5G-4 1.5 5.0 3.8
S3300-2R2G-4 2.2 5.8 5.1
S3300-004G-4 4 10.5 9
S3300-5R5G-4 5.5 14.6 13
S3300-7R5G-4 7.5 20.5 17
S3300-011G-4 11 26 25
S3300-015G-4 15 35 32
S3300-018G-4 18.5 38.5 37
S3300-022G-4 22 46.5 45
S3300-030G-4 30 62 60
S3300-037G-4 37 76 75
S3300-045G-4 45 92 91
S3300-055G-4 55 113 112
S3300-075G-4 75 157 150
S3300-090G-4 90 180 176
Selection note: The model table verifies the S3300 drive platform. Confirm the final cabinet, logic board, limiter, sensors, braking hardware and site wiring for the selected construction-hoist solution.

المواصفات الفنية

Item Verified specification
Input class Three-phase 380V
Output frequency 0-150Hz
أوضاع التحكم V/F, open-loop vector and closed-loop vector
Startup torque 150% at 0.5Hz V/F; 200% at 0.5Hz open loop; 200% at 0Hz closed loop
Speed range 1:100 open loop; 1:1000 closed loop
Overload 150% for 60s; 180% for 3s
Model range 0.75-90kW verified in drive table
Options / project configuration: Voice module, load limiter, encoder, soft-limit sensors, braking components, status panel and enclosure are project-dependent.

التطبيقات النموذجية

رافعات مواد البناء
رافعات أفراد مواقع البناء
تحديث مصاعد البناء
Twin-cage hoist panels
Rental fleet refurbishment
مشاريع OEM للتحكم في الرافعة

Information Required for Selection

  • Traction or door motor nameplate: power, voltage, current, frequency and motor type
  • Encoder type, signal format, resolution and required PG card for closed-loop systems
  • Elevator type, rated speed, load, travel height, floor count and duty cycle
  • Brake coil, braking resistor, UPS rescue supply and safety-chain arrangement
  • Control interface, I/O count, communication protocol and panel compatibility
  • Site temperature, altitude, cable length, quantity and destination

A dependable quotation requires the complete operating profile, not only the nominal power. IDEEI reviews voltage, current, source or motor data, duty, environment, required options and destination together so the final configuration, accessories, protection devices and commercial scope can be stated clearly.

Engineering & Installation Notes

The inverter or integrated controller is one part of the elevator control and safety system. Door circuits, mechanical brake, safety chain, final limits, rescue power and inspection controls remain system-level responsibilities. Commission motor data and encoder interfaces only with the car secured and qualified personnel present. Verify braking energy, resistor duty, contactor sequence and local elevator code before passenger service.

Installation and commissioning must be completed by qualified electrical personnel. Isolate all energy sources before wiring, verify terminal functions against the current manual, provide protective devices and grounding, and apply the published derating guidance for altitude, temperature, enclosure and cable length. Product-page data supports preliminary selection and does not replace project engineering or local code compliance.

الأسئلة الشائعة

Can this drive control both PMSM and asynchronous motors?

Motor support depends on the selected S3300 all-in-one control mode and hardware. Send the motor nameplate and encoder details so the correct model, PG card and tuning procedure can be confirmed.

What is the difference between open-loop and closed-loop control?

Open-loop vector control estimates motor operation without encoder feedback. Closed-loop vector control uses a compatible encoder and PG interface for higher low-speed and zero-speed performance.

Is UPS rescue operation included?

UPS or battery rescue functions are series- and project-dependent. The emergency power rating, wiring, travel logic, contactors and local safety requirements must be engineered as a complete system.

Can the inverter be selected only by motor kW?

No. Rated motor current, elevator load, speed, duty cycle, braking energy, motor type, encoder, cable length and ambient conditions all affect final selection.

What should be sent for a quotation?

Send the motor nameplate, elevator type, load, speed, travel height, floor count, encoder, brake arrangement, control-panel information, quantity and destination.

Engineering selection & bulk orders

Send the nameplate. We size the drive.

Send the required electrical and application data, quantity and destination. Our team will confirm the suitable model, options and quotation scope.

اطلب عرض سعر
Email Us
WhatsApp

Email: [email protected] · WhatsApp: +86 183 5724 1165

Talk to an engineerFACTORY-DIRECT · MON–SAT 8:30–17:30 (GMT+8)